Appendix C: Settings
Alarm Listing
Alarm Display Description
BATTERY LOW
Battery Low Warning
BATT. TOO HIGH
Battery High Shutdown
BATT. TOO LOW
Battery Low Shutdown
CURRENT LIMIT
At the Inverter current limit
BROWNED OUT
Shutdown because the inverter output voltage has been too low for
too long
BRICK FAULT
Power stage shutdown
XFRMR OVERHEAT
Transformer overheated
BRICK OVERHEAT
The power stage overheated
BATT. OVERHEAT
The batteries overheated. Note: Battery temperature compensation
must be ON
SYS. OVERHEAT
The internal temperature sensor reported >60 degrees C.
SURGING...
The load is greater than the inverter current limit; not limiting yet.
BAD GRID FREQ.
The utility or generator frequency is bad. (The voltage might be
OK).
PHASE MISMATCH
Line 1 and Line 2 voltages don't agree.
NO PHASELOCK
The transfer relay has not yet energized. The voltage and
frequency of the grid might be OK.
GRID L1-N BAD
Bad phase voltages
GRID L2-N BAD
Bad phase voltages
OPEN FUSE
The small inverter has blown its fuse
SOFTWARE FAULT
Software error - Checksum
BATTERY DEAD
Battery Low Shutdown, no charging. < 1/2 Battery Low Shutdown
value.
INVERTING
Normal
INVERTING-SMAL
Inverting “low power” with small inverter
L1-N OUT BROWN
L1 in current regulation mode (brown-out)
L2-N OUT BROWN
L2 in current regulation mode (brown-out)
L1 IN SURGING
L1 Coming up on APM limit
L2 IN SURGING
L2 Coming up on APM limit
L1 APM LIMIT
L1 is at APM Limit
L2 APM LIMIT
L2 is at APM Limit