Installation manual

RE Owners Manual
4-2
Copyright
2001 Phone: (614) 771-271 RE-4500
Vanner Inc. FAX: 614-771-4904 Installation Manual
4282 Reynolds Dr. www.vanner.com Rev 10d
Hilliard Ohio 43026 RE Owners_Manual_Rev10d D99988
INCORPORATED
INCORPORATEDINCORPORATED
INCORPORATED
(1) Knockout for High Current DC Wiring
This knockout provides for the routing and termination of high
capacity DC cables from batteries, RE-SLM, RE-DCM to the
RE-4500 Inverter/Charger.
This knockout provides access (from either the right side or the
left side of the inverter) to the DC Wiring Raceway.
This knockout matches up with the high capacity DC knockout
on Vanner accessories such as the DC Control Module (RE-
DCM), the RE48-SLM (Sun Lynx Module), and the AC
Control Module (RE-ACM). This is a standard size 2 ½”
conduit knockout.
(2) Knockout for Low Current DC Control Wiring
These knockouts provide for the routing and termination of
low capacity DC Control Wiring.
These knockouts provide access (from either the right side or
the left side of the inverter) to the DC Wiring Raceway.
These knockouts match up with the low current DC/Control
knockouts on Vanner accessories such as the DC Control
Module (RE-DCM), the RE-SLM (Sun Lynx Module), and the
AC Control Module (RE-ACM). This is a standard size ¾”
conduit knockout.
(3) Knockout for AC Wiring
This knockout provides for the routing and termination of AC
Wiring.
This knockout provides access (from either the right side or the
left side of the inverter) to the AC Wiring Raceway.
This knockout matches up with the AC knockout on Vanner
accessories such as the AC Control Module (RE24-ACM), the
RE48-SLM (Sun Lynx Module), and the DC Control Module
(RE24-DCM). This is a standard size 1 ¼ “ conduit knockout.