Important Safety Instructions
3-3
Copyright
2001 Phone: (614) 771-271 RE-4500
Vanner Inc. FAX: 614-771-4904 Installation Manual
4282 Reynolds Dr. www.vanner.com Rev 10d
Hilliard Ohio 43026 RE Owners_Manual_Rev10d D99988
INCORPORATED
INCORPORATEDINCORPORATED
INCORPORATED
N
Neutral
This symbol denotes that this termination
is used for the middle wire of a 240 Vrms
3 wire system consisting of Phase 1
(Black wire), Neutral (White wire), and
Phase 2 (Red wire).
L2
Phase 2
This symbol denotes that this termination
is used for the lower phase of a 240 Vrms
3 wire system consisting of Phase 1
(Black wire), Neutral (White wire), and
Phase 2 (Red wire).
GND
Ground
This symbol denotes that this termination
is used for a ground connection (Green
wire).
Safety Instructions
Caution
Read owners manual BEFORE wiring or powering up the RE-4500.
Caution
DO NOT cover or obstruct ventilation openings. DO NOT mount in
a zero-clearance compartment. Overheating may result.
Warning
Under high ambient temperature / high-power-output conditions
some parts of the inverter may become hot enough to cause
burns. The unit should be installed so that it is not to be contacted
by personnel.
Warning
This equipment employs components that tend to produce arcs
and sparks. To prevent fire or explosion, DO NOT install in
confined areas or compartments that contain batteries or
flammable gases and materials.
Warning
Improper use of this product may result in risk of electrical shock.
Both AC and DC voltage sources are terminated inside this
equipment.