Safety Features
When away from home for an extended period
of time or as a child safety feature to prevent
accidental ignition of the replace, receiver
ON/OFF/REMOTE switch should be in the
OFF position.
Auto Shutoff Feature
1. If the average room temperature reaches
a range of 82° F (28° C) to 92° F (33° C),
the hand-held remote control will perform
a safety override and shut the replace off.
This feature is not available in the MANU
mode.
2. The receiver continuously receives sig-
nals from the hand-held remote to control
the room temperature. If the hand-held re-
mote is misplaced, obstructed, or for any
reason cannot transmit to the receiver,
the receiver will shut off the replace. This
will occur in 8 or more minutes depending
upon location of remote transmitter and
strength of batteries.
Key Pad Lock Feature
This feature allows the user to lock/unlock
keypad on hand-held remote in MANU or
AUTO mode to prevent inadvertent opera-
tion (i.e. children operating hand-held remote
OPERATION
Continued
INSPECTING BURNERS
Figure 36 - Correct Pilot Flame Pattern
Pilot Burner
Figure 37 - Incorrect Pilot Flame Pattern
Pilot Burner
Natural Gas
Pilot Burner
Thermocouple
Pilot Burner
Thermocouple
Natural Gas Propane/LP Gas
Propane/LP Gas
control, etc.). The keypad is locked in either
on or off. Press POWER and LOCK buttons
together to turn unit on or off.
OPTIONAL BLOWER
OPERATION
Locate blower switch by opening lower louver
on replace insert. Blower switch is located at
lower left inside louver door.
This thermostat-controlled blower has three
settings: ON, OFF and AUTO. In the ON
position, blower will operate constantly. In
the OFF position, blower will not operate.
In the AUTO position, blower will start when
thermostat senses a sufcient increase in
rebox temperature.
Note: Your gas logs and thermostat blower
will not turn on and off at the same time. The
replace insert may run for several minutes
before blower turns on. After heater modulates
to pilot position, blower will continue to run.
Blower will shut off after rebox temperature
decreases.
Note: It is safe to operate replace insert with
blower turned off. However, blower helps dis-
tribute heated air from replace insert.
Check pilot ame pattern and burner ame
patterns often.
PILOT FLAME PATTERN
Figure 36 shows a correct pilot ame pattern.
Figure 37 shows an incorrect pilot ame pat-
tern. The incorrect pilot ame is not properly
heating the thermocouple. When the thermo-
couple cools, the heater will shut down.
If pilot ame pattern is incorrect, as shown
in Figure 37
• turn heater off (see To Turn Off Gas to Ap-
pliance, page 20)
• see Troubleshooting, page 25
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be blue
and have no yellow or orange color.