Installation manual

www.fmiproducts.com
113195-01K 19
OPERATION
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a re or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting
the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the oor because some
gas is heavier than air and will settle
on the oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas suppliers instructions.
If you cannot reach your gas supplier,
call the re department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don’t try to repair it, call a quali-
ed service technician or gas supplier.
Force or attempted repair may result in
a re or explosion.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualied service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been under
water.
LIGHTING
INSTRUCTIONS
WARNING: You must oper-
ate this heater with the replace
insert screen in place. Make
sure replace insert screen is
installed before running re-
place insert.
O
F
F
P
I
L
O
T
L
O
I
H
AU TO
OFF
ON
O
N
Figure 31 - Control Knob and Ignitor
Button Location (Shown as Supplied, No
Control Options)
Control
Knob
Ignitor Button
Flame
Adjustment
Knob
Selector Switch
NOTICE: During initial operation
of new replace insert, burning
logs will give off a paper-burning
smell. Open damper or window
to vent smell. This will only last
a few hours.
1. STOP! Read the safety information col-
umn 1.
2. Make sure equipment shutoff valve is fully
open.
3. Set switch to OFF position.
WARNING: Burners will
come on automatically within
one minute when the remote
selector switch is in the ON posi-
tion after the pilot is lit.
4. Press in and turn control knob clockwise
to the OFF position.
5. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information in column 1. If
you don’t smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
to the PILOT position.
Press in control knob for ve (5) seconds
(see Figure 31).
Note: You may be running this heater
for the rst time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.