Specifications

046-08OP-001D S/N 046050010021 - UP
28
Every 2000 Service Hours or 1 Year
Hydraulic System Oil - Change
Accumulator
This system contains high pressure gas. Failure to follow the instructions and warnings could cause an explosion,
resulting in possible injury or death. Do not expose to fire. Do not weld. Do not drill. Do not remove any hydraulic
system lines, taps or parts until pressure has been relieved. Relieve pressure before discharging. See Operation and
Maintenance Manual "Accumulator - Relieving Charge". See Operation and Maintenance Manual "Accumulator" for
charging and discharging. See your Dealer for tools and detailed information.
Accumulator must be charged with dry nitrogen (N
2
) gas by qualified personnel only. The accumulator must be at the same
temperature as the surrounding air before being checked or charged. Charge the accumulator depending on the ambient air
temperature according to the table below. Access the accumulator to charge from the rear of the tractor, above the tow-
winch drive.
Figure 30: Accumulator located under access panel below operator seat.
Ambient air temperature [°C (°F)] Accumulator precharge pressure [kPa (psi)]
± 70 kPa (10 psi)
-7°C (20°F) 3100 kPa (450 psi)
-1°C (30°F) 3170 kPa( 460 psi)
4°C (40°F) 3240 kPa (470 psi)
10°C (50°F) 3310 kPa (480 psi)
16°C (60°F) 3375 kPa (490 psi)
21°C (70°F) 3445 kPa (500 psi)
27°C (80°F) 3515 kPa (510 psi)
32°C (90°F) 3580 kPa (520 psi)
38°C (100°F) 3650 kPa (530 psi)
43°C (110°F) 3720 kPa (540 psi)
49°C (120°F) 3790 kPa (550 psi)
Table 6: Accumulator precharge pressure for ambient air temperature
046-05-60-001
FR
O
NT
CHARGE
FROM
TRACTOR