User manual

83
PAD Log
When enabled, as data passes through the PAD, a copy is stored in a log file located on the modem at
/tmp/padlog. The log will stop saving data when full and data is lost at modem reset.
3.8.2 INTERNAL SERIAL
The Internal Serial screen is used to configure the internal RS232 Serial Port parameters and Packet Assembler and
Disassembler (PAD) functionality. The PAD feature forwards requests that come in on a specific port to the internal serial
port.
Figure 47: Serial Internal Serial
Serial Port Configuration
Baud Rate
Sets the baud rate of the serial port. Settings may range from 300 to 115,200 bits per second. The default baud
rate is 115,200 bps.
PAD Settings
Remote IP Address
Sets the IP address of the device using the PAD functionality
Remote Port
Sets the port number used by the remote device to accept requests from the Vanguard SC
Local Port
Sets the port number used by the Vanguard SC to accept requests from the remote device