Installation manual

Part No. T0249-01, Rev A
April, 2002
Installing Software Images and Bootprom Software Updates Page 10 of 55
Figure 2. Bootprom Revision Example
2) Use the Procomm application to update the software images or Bootprom. Open
the Procomm application to get a Data Terminal Window. The settings should be
9.6k, N-8-1, and RAW-ASCII transfer mode. Use a regular Control Terminal
Port (CTP) connection.
3) Activate a Force Cold-Load (16.12.y.y):
Flash Memory->Force-Cold-Load->yes
Cold Boot the node (7.5.y):
Boot->Node (cold)->yes
A Download Coldloader prompt from the (CTP) displays.
4) Choose an appropriate speed coldloader indicated in the current bank column of
the table below. Typically the c73cv115.xrc file is used.
Current Bank Kbps
c73cv115.xrc 115
c73cv192.xrc 19.2
c73cv288.xrc 28.8
c73cv384.xrc 38.4
c73cv576.xrc 57.6
c73cv96.xrc 9.6