Specifications

Application Views Supported Applications
Device Management Page 78 Motorola Vanguard
signallingType
Select the E&M signalling type. Valid values are:
i, ii, iii, v, and nc. This parameter is displayed
for DSPM/E&M and skipped for FXS, FXO, and
all virtual port types.
ELeadFilter
Selection for E lead filter enable or disable option.
This parameter is displayed for DSPM/E&M and
skipped for FXS, FXO, and all virtual port types.
Valid values are: enabled, disabled, and nc.
HybridFXS
Hybrid balance filters and termination type based
on country. Table 19 displays the valid filters:
This parameter is displayed for DSPM/FXS and
skipped for DSPM/E&M, DSPM/HC(FXO) and all
virtual port types.
HybridEAndM2
Hybrid balance filters and termination type based
on country. (Only for E&M-2wire interfaces.)
Table 20 displays valid filters and descriptions:
Table 19: Hybrid FXS Filters
Filter Description
sixHundred 600 ohm interface for USA, Japan and
Ireland.
Canada 600 ohms with 2.16 uF.
Germany 220 ohms in series with (820 ohms in
parallel with 115nF).
UK 300 ohms in series with (1K ohms in
parallel with 220nF).
Belgium 150 ohms in series with (830 ohms in
parallel with 72nF).
France 215 ohms in series with (1K ohms in
parallel with 137nF).
nc Skipped during configuration.
Table 19: Hybrid FXS Filters
Filter Description