Specifications

Application Views Supported Applications
Device Management Page 34 Motorola Vanguard
AutocallAdd
If configured, the Autocall Mnemonic references a
remote address which will be called by the LAN
Connection.
AutocallTime
The time interval in seconds between call
attempts when auto calling.
AutocallAttempt
The number of times that the LAN Connection will
attempt to autocall a remote destination. A value
of zero will allow unlimited attempts.
ConnectionID
The number of the remote LAN Connection or the
FRA Station number that this LAN connection will
attempt to connect to if configured for autocall.
Billing
This controls whether billing (accounting) records
will be created for calls on this LAN Connection.
Table 12 displays the valid options and
descriptions:
TrafficPriority
The Traffic Priority of this LAN Connection. Valid
values are: low, med, high, exp (Expedite
Priority), nc, and newvalLow (same as low).
ConnQueue
The maximum number of bytes that will be
queued for this LCON before transmission on the
WAN link. It is recommended that this parameter
be set for two seconds of data on the WAN link.
Encap
The data encapsulation type used over this LAN
Connection. Valid values are: codex, rfc1294,
rfc877, nc, and newvalCodex (same functionality
as codex).
StartupConn
Controls whether the circuit is established at
startup or established when required for data
Table 12: Billing
Billing Description
off Billing records will not be created.
on Billing records will be created.
nc Skipped during configuration.
newvalOff Same functionality as “off”.