Technical information
Part No. T0289, Rev A
August, 2008
Boot Prom Software Updates Page 29 of 97
Figure 1. Bootprom Revision Example
2) Use the Procomm application to update the Bootprom. Open the Procomm
application to get a Data Terminal Window. The settings should be 9.6k, N-8-1,
and RAW-ASCII transfer mode. Use a regular Control Terminal Port (CTP)
connection.
3) Activate a Force Cold-Load (16.12.y.y):
Flash Memory->Force-Cold-Load->yes
Cold Boot the node (7.5.y):
Boot->Node (cold)->yes
A Download Coldloader prompt from the (CTP) displays.
4) Choose an appropriate speed coldloader indicated in the current bank column of
the table below. Typically the c73cv115.xrc file is used.
c) Select Option 1, Node Stat, from the Status/statistics menu. The Node
Stats’ displays the Bootprom Revision: 7300 Series Examples:
Version 1.10, 1.11, 1.30, 1.40, 1.50, 1.51, Version 2.00, or Version 3.00.
Note
Refer to the Bootprom Directory table in Step 9.
Step Action
Current Bank Kbps
c73cv115.xrc 115