Installation manual
Part No. T0001-43, Rev B
February, 2003
Software Improvements Page 34 of 99
• Rx State = 1000 and Voice State = IDLE_UNCON - This means that the port
has booted to the correct state.
Figure 10 shows that the port statistics page reports the following conditions as the
current port state:
• Rx State = 0000 and Voice State = IDLE_UNCON - This means that the port
has booted to the incorrect state.
Figure 10. Detailed Port Statistics - Incorrect State
If the Rx State = 0000 this means that:
• the port has booted to an incorrect state
• the port is not physically connected to a PBX Station or CO trunk
This is fixed.
Vanguard 6400 Series Event Log Port Information
When a Vanguard 6455 is defaulted with an ISDN data card in slot 1 the node comes
up and alarms appear in the event log for ports 51-53, even if a quad card is not
installed. (Ports 51-53 are for the quad FXS/FXO card.) If you have a quad FXS port
installed and configured in slot 2, and you remove this card and install a single FXO
the log should show a problem. The node comes up, but there is no log that states
“cannot boot ports 61-64 because of a hardware mismatch”. (DRCaa23067)
This is fixed.
Vanguard 6455 PRI-DATA and PRI-Voice Alarm Errors
Upon completion of a node boot, level one alarms are generated for every virtual
port mapping table entry with Virtual Port Type configured as PRI-DATA or
PRI-VOICE. Example: (1) 102 20-JUN-2001 08:25 Assert 897 vpmt.c
(DRCaa22532)
This is fixed.