User guide
Press and hold MODE/PREF key for 3 seconds to access
the setting menu.
NOTE: You can exit Preferences setting by pressing
on MODE/PREF for 3 seconds any time in the
process, or wait 60 seconds. The modified values
will be kept in memory.
MODE
PREF
If the control is set for the very first time, the current day
will be the first setting to be made: MON (for Monday) will
flash on screen.
SMART
SET
MODE
PREF
NOTE: While setting Preferences, the corresponding setting value flashes (e.g.: while setting
current hour, hour is flashing).
Use the arrow keys to select value.
OR
Press SET key to confirm the selected preference and
go to next setting.
SET
3 SEC.
SETTING PREFERENCES PROCEDURE
2. CONTROLS (CONT’D)
HOW TO SET PERIODS FOR PROGRAM MODE
The Program Mode allows the user to customize the operation of his/her ventilation unit, for
week and weekend days. All days are divided in 4 periods. The periods starting hour and
ventilation speed are factory set (see below).
DAILY PERIODS DEFAULT SETTINGS
PERIOD STARTING HOUR MODE
PERIOD 1 (MORNING) 6:00 AM MIN
P
ERIOD 2 (DAY) 9:00 AM 20 MIN/H
PERIOD 3 (EVENING) 5:00 PM MIN
P
ERIOD 4 (NIGHT) 11:00 PM 20 MIN/H
9
2.3 PLATINUM MAIN CONTROL (FOR HRV 90H-V ECM, ERV 90H-V ECM
AND 60H NOVO+ UNITS ONLY) (CONT’D)