User guide

2. CONTROLS (CONTD)
2.4 DECO-TOUCH MAIN CONTROL (ALL UNITS) (CONTD)
14
In the operating modes MIN, MAX, 20 min./h. and RECIRC (if available), the user can select
a dehumidistat override so that if the relative humidity (RH) in the house exceeds the RH
setting previously stored, the ventilation unit will exchange in high speed until the target
indoor RH setting is reached.
An air exchanger is not a dehumidifier, but it can change the indoor relative humidity by
bringing in drier or more humid air from outside during non heating season.The dehumidistat
override function is useful to reduce indoor RH when the outdoor air is cool and dry during
the heating season. Select a target RH between 30% and 55% according to your comfort.
When outdoor relative humidity is high (e.g. in summer), turn off the override by pressing OK
until the RH display disappears.
When the dehumidistat override is activated, the AUTO indicator will appear on
LCD screen to show that the actual mode is being overridden. Also, the relative
humidity appears (if it was not shown, see example at left). Once the target
humidity level is reached, the unit goes back into its original operating mode and
AUTO disappears from LCD screen.
NOTE: If the actual mode is MAX, only the relative humidity level appears on screen, AUTO
label willl not appear.
To engage the humidity override, press OK. The actual indoor RH and the %HUM label
appear on LCD screen.
NOTE: If the actual RH is less than 20%, then the humidity indicator will display “LO”, and if
the actual RH is greater than 80%, then the humidity indicator will display “HI”.
To turn off the dehumidistat override, press OK again. The RH and %HUM display will
disappear from LCD screen.
DEHUMIDISTAT OVERRIDE SELECTION
The maintenance indicator is represented by an M in a rounded
triangle, at the top of the house (see at right). If this indicator
is flashing, perform the regular maintenance, and if it is not
flashing, perform the annual maintenance (refer to Section 3).
RESETTING MAINTENANCE INDICATOR: Press simultaneously on both arrow buttons,
maintenance indicator will disappear from LCD
screen.
AND
MAINTENANCE INDICATOR
After a power failure, the wall control returns to its original operation mode. All settings are
kept in memory.
POWER FAILURE