User guide

2. CONTROLS (CONTD)
2.4 DECO-TOUCH MAIN CONTROL (ALL UNITS) (CONTD)
Setting the relative humidity level allows to select the maximum desired indoor humidity level
(in percentage). This value will be used to start the dehumidistat override (air exchange on
high speed).
3 sec.
Press and hold OK for 3 sec. to access the setting menu.
The backlight will be activated during all the procedure.
The relative humidity arrow and value will flash
(default setting: 45%).
OR
Use UP or DOWN arrow to change
the value. The value changes by 1%
increments. Lower value: 30%. Higher
value: 55%. Still flashing.
Press OK button to accept new value and go to next setting.
NOTE: For 90H-V, press OK button to accept new value and
quit setting menu.
OR
OR
Use UP or DOWN
arrow to change
to recirculation in
standby.
Press OK button to accept and
quit setting menu.
Recirculation arrows are turning and rE
flashes to show that RECIRCULATION²
is in standby.
Two lines are flashing to show that
OFF¹ is in standby
(default configuration setting).
Press OK button to accept and
quit setting menu.
HOW TO SET THE RELATIVE HUMIDITY (RH) LEVEL AND CHOOSE BETWEEN
OFF IN STAND BY OR RECIRCULATION IN STAND BY*
¹OFF IN STANDBY*: On 20 min./h. mode, the ventilation unit is OFF during 40 minutes and
exchanges air with the outside on low speed during the remaining
20 minutes of the hour; this is the default value.
RECIRCULATION
IN STANDBY*: On 20 min./h. mode, the ventilation unit recirculates the inside
air for 40 min. on high speed and exchanges air with the
outside on low speed during the remaining 20 min. of the hour.
13
*OFF in standby and RECIRCULATION in standby are not available for 90H-V units.