Pair specifications
Conductor Material Bare ultra pure oxygen free copper wire
Stranding 28 x 0.10 (0.22mm
2
) AWG 24/28
Insulation Material Polypropylene
Average thickness 0.22mm
Diameter 1.00mm ±0.10
Colour coding IEC 189-2 appendix A
Cabling Type Twisted pair
Lay length ~28mm
Screen Type 24µm Aluminium/polyester foil >150% coverage
Drain wire 19 x 0.12 (0.22mm
2
) AWG 24/19
Jacket Material PVC composite Sapphire blue RAL 5003
Average thickness 0.34mm
Overall diameter 2.70mm ±0.10
Overall Jacket
Overall jacket Material Flexible PVC composite
Colour Sapphire Blue RAL 5003
Average thickness See characteristics by stock code
Bend radius 10 x overall diameter
Physical properties un-aged
Jacket (at 60ºC) Tensile strength >12.5N/mm
2
Elongation >100%
Heat shock test 150 ºC x 1 hour - no cracks
Electrical characteristics
Resistance Conductor Ohm/Km <90
Shield <70
Insulation M Ohm/Km >5000
Capacitance Core to core pF/m 100 nominal
Core to shield 200 nominal
Test voltage 500 Vdc x 1 minute OK
Characteristics by stock code
Stock code Overall diameter mm Jacket thickness mm Weight Kg/km Construction and lay up
268-202-060 7.50 1.25 68 2 pairs, 100mm lay length
268-204-060 9.60 1.55 105 4 pairs, 95mm lay
268-208-060 12.20 1.50 175 Cotton fillers +1 pair, 1st layer 7 pairs, 130mm lay
268-212-060 14.30 1.50 228 Cotton fillers + 3 pairs, 1st layer 9 pairs, 120mm lay
268-216-060 16.30 1.80 310 Cotton fillers, 1st layer 5 pairs, 2nd layer 11 pairs, 100/200mm lay
268-224-060 20.80 2.20 480 Cotton fillers+ 2 pairs, 1st layer 8 pairs, 2nd layer 14 pairs, 150/220mm lay
268-232-060 22.10 2.20 590 Cotton fillers + 5 pairs, 1st layer 10 pairs, 2nd layer 17 pairs, 150/150/220mm lay
268-240-060 25.00 2.20 720 Cotton fillers + 1 pair, 1st layer 6 pairs, 2nd layer 14 pairs, 3rd layer 19 pairs,
110/200/250mm lay
268-248-060 26.30 2.20 855 Cotton fillers+ 3 pairs, 1st layer 9 pairs, 2nd layer 15 pairs, 3rd layer 21 pairs,
110/200/250mm lay
• Maximum reel length 500 metres