Owner manual

PAGE 1
WARNINGS
DO NOT REPLACE ANY ITEM ON FILTER WHILE IT IS PRESSURIZED.
DO NOT OPERATE A LEAKING FILTER. TAKE FILTER OUT OF SERVICE IMMEDIATELY.
DO NOT OPERATE ABOVE MAXIMUM WORKING PRESSURE (MWP) AT MAXIMUM OPERATING TEMPERATURE (°F).
(COALESCING)
IN/OUT
(PARTICULATE)
OUT/IN
FEBRUARY 2012
P/N 32-0313
REV A
FLOW DIRECTION THROUGH ELEMENT
OUTLET
INLET
PRODUCT PURPOSE & FUNCTION:
Van Air's AHP series lters are designed to remove contaminants from compressed air systems. Available in 1/4" to 2" con-
nection sizes and ow capacities from 94 to 1882 scfm (at MWP @ 725 psig) in 8 housings and 9 ltration grades, the AHP series can
remove oil aerosols, oil vapors, water and particulates. Housings are made of cast aluminum and coated with black high temperature
paint for corrosion resistance. All units include push-on elements with durable polyester drain layer (except RD grade).
OPERATING CONDITIONS
MAXIMUM WORKING PRESSURE
All Models
OPERATING TEMPERATURE
Minimum
Maximum
MAXIMUM RECOMMENDED INLET TEM-
PERATURE
AA, A, RAA, RA, RB, and RC Series
B Series
C Series
RD Series
725 PSIG
35°F
248°F
225°F
175°F
125°F
80°F
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
AHP SERIES
COMPRESSED AIR FILTERS
INLET
OUTLET
FILTRATION GRADES
APPLICATION ELEMENT
GRADE
PURPOSE NOMINAL
PARTICLE
REMOVAL
ELEMENT FLOW
DIRECTION
OIL
REMOVAL
(LIQUIDS)
AA
Extra Coarse
Coalescing
25.00 μ IN/OUT
A
Coarse
Coalescing
5.00 μ IN/OUT
B
General Purpose
Coalescing
1.00 μ IN/OUT
C
High Efciency
Coalescing
0.01 μ IN/OUT
PARTICULATE
REMOVAL
(SOLIDS)
RAA
Extra Coarse
Particulate
25.00 μ OUT/IN
RA
Coarse
Particulate
5.00 μ OUT/IN
RB
General Purpose
Particulate
1.00 μ OUT/IN
RC
High Efciency
Particulate
0.01 μ OUT/IN
OIL VAPOR
REMOVAL
RD
Vapor Absorbing
0.01 μ OUT/IN

Summary of content (4 pages)