SDS

Page: 4
SAFETY DATA SHEET
Revision Date: 11/12/2015
Print Date: 9/12/2016
SDS Number: R0412087
Valvoline DEXRON-VI FULL SYNTHETIC
AUTOMATIC TRANSMISSION FLUID
822405
Version: 1.3
4 / 11
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
Components
CAS-No.
Value type
(Form of
exposure)
Control
parameters /
Permissible
concentration
Basis
HYDROTREATED LIGHT
PARAFFINIC DISTILLATE
64742-55-8
ACGIH
ACGIHLIS_P
ACGIHLIS_P
REL
5 mg/m3
Mist.
NIOSH/GUID
E
STEL
10 mg/m3
Mist.
NIOSH/GUID
E
PEL
5 mg/m3
Mist.
OSHA_TRAN
S
Engineering measures
:
General room ventilation should be adequate for normal
conditions of use. However, if unusual operating conditions
exist, provide sufficient mechanical (general and/or local
exhaust) ventilation to maintain exposure below exposure
guidelines (if applicable) or below levels that cause known,
suspected or apparent adverse effects.
Personal protective equipment
Respiratory protection
:
No personal respiratory protective equipment normally
required.
Eye protection
:
Not required under normal conditions of use. Wear splash-
proof safety goggles if material could be misted or splashed
into eyes.
Skin and body protection
:
Wear as appropriate:
Safety shoes
Wear resistant gloves (consult your safety equipment
supplier).
Hygiene measures
:
General industrial hygiene practice.
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Physical state
:
liquid
Colour
:
red