Specifications
4
APPLIANCE SPECIFICATIONS
FEATURE MODEL
276N 276P
GAS NATURAL PROPANE
INLET PRESSURE MAX 10.5 14
(Ins w.c.) MIN
1
511
MANIFOLD PRESSURE MAX 4.2 9.7
(In w.c.) MIN 3.8 9.3
INPUT MAX (Btu/h) 25,000 28,000
HEIGHT (Ins.) 26
3
/
8
”
WIDTH (Ins.) 25
DEPTH (Ins.) 8
3
/
8
”
BLOWER ACCESSORY
2
VF171 or VFT171
Notes:
1. For purposes of input adjustment.
2. Contact your dealer for details of the blower accessory.
3. WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater
This appliance is design certified for use in the USA by International Approval Services to ANS Z21.11.2b - 1998 (Unvented gas fired
room heaters).
INSTALLATION
CODES
Installation requirements vary with the locality. The installation
must conform with local codes or, in the absence of local codes,
with the latest edition of the National Fuel Gas Code ANSI
Z223.1. This appliance may be installed in an aftermarket
manufactured (mobile) home where not prohibited by state or
local codes.
Aftermarket: Completion of sale, not for purpose of resale, from the
manufacturer.
This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases.
CLEARANCES
The minimum clearances to combustible surfaces are shown in
figure 1.
Allow sufficient clearances for comfortable operation of the
controls and easy access for cleaning and servicing.
If the appliance is intended to be installed on carpeting, tile or
other combustible flooring other than wood, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
Fig. 1 Appliance dimensions and clearances to combustible materials