Owner`s manual

10
3” dia. Aluminum Liner
Rough-in the 3” diameter vent liner into existing chimney system being careful not to tear or damage the liner in the
process. Leave plenty of liner at the bottom end if the heater will be connected while on the hearth—see diagram
in Connect Liner to the Firebox section. When connecting the liner in this manner, 
 so the slack liner can be lifted after the insert is in place.
 
Unpack appliance.
Remove window.
Remove log pack from rebox.
Strip rebox down by removing:
Burner module (4 screws);
Vent plate;
Support Legs (2 screws per leg)


1/4 Turn
Spring-Loaded
Fastening Studs (2)
Remove Window
The size of the existing replace cavity will affect the method of installation. Smaller replaces, particularly factory-
built zero clearance replaces, will require the RF24 rebox to be disassembled and then reassembled inside the
replace. Plan your installation accordingly.
Remove Vent Plate
Remove Window
Remove
Burner
Module
(4 screws)
Remove
Support Legs
(2 screws each)
Vent Liner Rough-In
Appliance Preparation