Operating instructions

77
Speci cations
Approvals & codes
These appliances are certi ed by ANSI Z21.88-2009/CSA
2.33-2009 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada and
USA. These appliances are for installation directly venting
through an outside wall or through the roof.
Model 650IRN is for use with natural gas.
Model 650IRP is for use with propane gas.
Conversion between fuels may only be done using the
approved conversion kits listed in the section Options.
These appliances comply with CSA P4.1-09 Testing
method for measuring annual replace ef ciencies.
The installation must conform with local codes or, in
the absence of local codes with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only quali ed
licensed or trained personnel should install these
appliances.
These appliances, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
Ratings
*Tested to CGA - 2.17-91 High Altitude Standard in
Canada. In the USA, installations may require deration
over 2,000 feet—check local codes.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to con rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Model 650IRN 650IRP
Gas Natural Propane
Altitude (Ft.) 0-4,500 *
Input Max. (Btu/h) 24,000 24,000
Input Min. (Btu/h) 6,500 13,000
Manifold pressure (in w.c..) 3.95 10.5
Min. Supply pressure (in. w.c.) 5.0 11.0
Max. Supply pressure (in. w.c.) 11.0 14.0
Supply Gas
Heater engine unit 650IRN is used with natural gas
installations.
Heater engine unit 650IRP is used with propane gas
installations.
The supply pressure must be between the limits shown
in the table above.
The supply connection is
inch NPT.
The opening for the gas
supply line is at the left
side of the appliance.
Wall Thickness
The vent system (when horizontally terminated)
is approved to pass through combustible wall
construction of up to 14 inches (36 cm) thick.
A non-combustible wall can be any thickness up to the
maximum horizontal run of vent pipe allowed for the
particular installation—see Venting section.
Venting options
Direct vent installations (solid piping)
A list of all approved venting accessories is shown on
pages 38–39 of this manual.
NOTE: An 817VAK Vent Adapter is required in all
cases when using vent components other than Valors
551DVK Standard Vent Terminal.
Direct Vent Co-Linear Installations ( exible piping)
Converts the appliance outlet collars to accept two
3-inch diameter ex liners for installation into existing
solid-fuel burning replaces and chimneys. Requires a
co-linear adapter at the appliance and either a co-linear
terminal or co-linear-to-co-axial adapter and terminal
at the top of the chimney. A list of approved venting
accessories is shown on pages 38–39 of this manual.
Floor/Hearth
This appliance is approved for installation directly on
combustible material such as plywood and so on. Vinyl,
carpet, and soft ooring require sheet metal extending
the whole width and depth under the appliance.
This appliance does not require a hearth. Combustible
ooring may extend up to the front of the unit.