Operating instructions

1
4000510/02
© 2005, Miles Industries Ltd. All rights reserved.
Note: This kit must be installed or serviced by a qualied installer, service agency or the
gas supplier. These instructions are to be used in conjunction with the main installation
instructions for the above listed models.
WARNING: If the information in these instructions is not followed exactly, a re or
explosion may result causing property damage, personal injury or loss of life.
GROUNDING: This power supply must be installed and grounded in accordance with
local codes, or in the absence of local codes, with the current Canadian Electrical Code
CSA C22.1. or in the USA the National Electrical Code ANSI/NFPA70 latest edition.
1. DESCRIPTION OF SYSTEM
The Models listed above have been designed to accommodate the installation of an air circulation
fan. Operated by a variable speed control and a thermally actuated switch, a fan is designed to
boost the natural convection through the heater; this may be a desirable feature dependent on
the replace location and room layout. The circulating fan may be installed before the heater
2. ELECTRICAL REQUIREMENTS
The fan kit requires a power supply of 120 Volts, 1 phase, 60 Hz. Full load current is less than
1 amp.
This power supply must be installed and grounded in accordance with local codes, or in the
absence of local codes, with the current Canadian Electrical Code CSA C22.1. or in the USA the
National Electrical Code ANSI/NFPA70 latest edition.
#555 CIRCULATING FAN KIT
INSTALLATION and OPERATING INSTRUCTIONS
CSA approved for use only with:
Valor model 530, RetroFire RF24 and Madrona MF28