Unit installation

16. SERVICING & PARTS REPLACEMENT
Always turn off the gas and allow the appliance to cool completely before
commencing any servicing. (The inlet ‘T’ connector on this appliance incorporates
an isolating valve)
Always test for gas soundness after refitting the appliance.
This product uses a fuel effect, a burner compartment rear wall and gaskets
containing Refractory Ceramic Fibres (RCF), which are man-made vitreous
silicate fibres. Excessive exposure to these materials may cause irritation to eyes,
skin and respiratory tract. Consequently, it is important to take care when
handling these articles to ensure that the release of dust is kept to a minimum. To
ensure that the release of fibres from these RCF articles is kept to a minimum,
during installation and servicing we recommend that you use a HEPA filtered
vacuum to remove any dust and soot accumulated in and around the fire before
and after working on the fire. When replacing these articles we recommend that
the replaced items are not broken up, but are sealed within a heavy duty polythene
bag, clearly labelled as RCF waste. This is not classified as “hazardous waste” and
may be disposed of at a tipping site licensed for the disposal of industrial waste.
Protective clothing is not required when handling these articles, but we recommend
you follow the normal hygiene rules of not smoking, eating or drinking in the work
area and always wash your hands before eating or drinking.
16.1 To remove the fascia.
Decadent
! Remove the bottom front casting.
! Lift the fire front casting clear by lifting the fire front
casting up and forward. This will release the locating
screw heads at the back of the casting from the keyholes in
the fascia sides.
! Remove the wiring loom connectors from the right
hand side of the gas valve.
! Remove the two screws securing the bottom of the
fascia to the sides of the convection box.
! Raise the fascia to allow the retaining lugs at the top to
clear the slots in the convection box hood and then lift
clear (See figure 37). Be careful not ttrap the wiring loom
when lifting clear.
Page 32
INSTALLER GUIDE
Figure 37. Fascia removal