Owner`s manual
Top vent connection, vertical vent rise
with horizontal rear termination (Fig.16)
12 of 48
Can be used with either #551DVK standard vent kit or #984
Dura-vent terminal cap and accessories.
Adapter #817VAK, one 90° vent elbow #990B and Dura-vent
pipe lengths will be required.
(See venting options section of this manual).
No more than two 90°elbows must be used.
Minimum Maximum
A: From floor to top
of vent duct
4ft
(122cm)
11ft
(335cm)
B: Back of appliance
to inside wall
3
1
/
4
in
(79mm)
-
C: Vertical pipe run 9in
(23cm)
8ft
(244cm)
D: Horizontal pipe
run
- 4ft 6in
(137cm)
E: Clearance to
combustible materials
above horizontal pipe
run
2
5
/
8
in
(6.7cm)
-
F: Clearance to
combustible materials
below horizontal pipe
run
1
5
/
16
in
(3.3cm)
-
G: Clearance to
combustible materials
all round vertical pipe
run and at sides of
horizontal pipe run
1
5
/
16
in
(3.3cm)
-
Figure 16
4.2.12 Top vent connection, vertical
vent rise with horizontal side
termination (Figs.16 &17)
Figure 17
Can be used with either #551DVK standard
vent kit or #984 Dura-vent terminal cap and
accessories.
Adapter #817VAK, one 90° vent elbow #990B
and Dura-vent pipe lengths will be required.
(See venting options section of this manual).
No more than two 90°elbows must be used.
All vertical dimension, pipe run and clearance
limits are as section 4.2.11.
4.2.13 Top vent connection, vertical
vent rise with horizontal side
or rear snorkel termination
The dimensional requirements in sections
4.2.11 and 4.2.12 apply.
Adapter #817VAK, one 90° vent elbow #990B, Dura-vent pipe lengths and a Dura-vent snorkel termination will be
required.
#942 Dura-vent thimble kit may also be necessary.
(See venting section of this manual).