Owner`s manual

Figure 11
4.2.6 Corner location, rear vent
connection, vertical rise,
horizontal termination
(Figs 9 & 11)
Can be used with either #551DVK standard vent
kit or #984 Dura-vent terminal cap and accessories.
Adapter #817VAK, two 90° vent elbows #990B and
Dura-vent pipe lengths will be required.
(See venting options section of this manual).
No more than two 90°elbows must be used.
All vertical dimensional limits are as section 4.2.3.
Figure 12
4.2.7 Rear vent connection, vertical
vent rise with through the roof
termination (Fig.12)
Adapter #817VAK, one 90° vent elbow #990B,
Dura-vent pipe lengths, a vertical vent terminal and
roof flashing will be required. Various other ceiling
or roof items may be necessary depending on the
particular installation (See venting options section
of this manual).
10 of 48
Figure 13
4.2.8 Rear vent connection, vertical
vent rise with offset and
through the roof termination
(Fig.13)
For situations where offset is necessary in
an attic to avoid obstructions or allow
useful space.
Adapter #817VAK, one 90° vent
elbow#990B, two 45° vent elbows #984,
wall straps, a vertical vent terminal, roof
flashing and Dura-vent pipe lengths will be
required. Various other ceiling or roof
items may be necessary depending on the
particular installation (See venting options
section of this manual).