Unit installation

as a stable, non-reactive hazardous waste and may be disposed at a landfill
licensed to accept such waste. Protective clothing is not required when
handling these articles, but we recommend you follow the normal hygiene rules
of not smoking, eating or drinking in the work area and always wash your
hands before eating or drinking. This appliance does not contain any
component manufactured from asbestos or asbestos related products.
2. APPLIANCE DATA AND EFFICIENCY
2.1 General information.
Under no circumstances is this fire to be converted to LPG. An LPG conversion kit
does not exist for this gas fire.
The appliance information label is located on a plate at the base of the fire. This can
be seen by removing the lower front casting / fire front.
Before continuing with the installation of this appliance please complete the
information on the last pages of the owner guide.
Page 8
© Baxi Heating U.K. Limited 2009.
Gas Natural
Inlet pressure 20mbar
Input - Max. (Gross) 3.65kW (12,454 Btu/h)
Input - Min. (Gross) 1.5kW (5,118 Btu/h)
Inlet pressure (Cold) 20.0 ± 1.0mbar (8.0 ± 0.4in w.g.)
Gas connection 8mm pipe
Main burner Simplex aerated
Burner injector Cat. 92 size 280
Pilot unit
Left side of firebox. Combined pilot jet, thermocouple sensor
and electrode. SIT ref. NGOP9706
Ignition Integral piezo on gas valve.
Aeration adjustment None required
Controls
Manual pilot and main burner off/on control (Right control).
Separate variable manual control for main burner (Left
control). Fitted with flame supervision device and integral
piezo igniter.
Walls
Minimum 102mm (4in.) thick.
Maximum 660mm (26in.) thick.
INSTALLER GUIDE