Unit installation

GAS CONSUMPTION
Model 541
Has a maximum natural gas input of 3.65kW (Gross)
Has a maximum natural gas output of 2.8kW
Has a minimum natural gas input of 1.5kW (Gross)
Has a minimum natural gas output of 1.13kW
OPERATING YOUR FIRE
The pilot may be left alight. It is advisable, however, that the pilot is turned off if the
premises are to be left unoccupied for a lengthy period.
For your safety the fire is fitted with a flame supervision device which will shut off the
gas supply if for any reason the pilot goes out. This device incorporates a fixed probe
which senses the heat from the pilot flame. If the probe is cool the device will prevent
any gas flow unless the pilot lighting knob is held in. This device also stops the fire
being turned back on until it is safe after it has been turned off.
If, for any reason, the fire goes out or if the fire is turned off, always wait at least six
minutes before attempting to relight
If the device starts to shut off the gas frequently, get expert advice.
The controls are shown in figure 3.
OWNER GUIDE
Figure 3. Controls