Unit installation

clear the slots in the convection box hood and then lift clear (See figure 35).
17.2 To remove window unit.
Remove the fascia (See section 17.1).
Unscrew and remove the three spring-loaded window-
fixing screws and bushes from the base of the window
frame (See figure 36).
Gently swing the base of the window frame forward
while lifting the frame upwards. The window should lift
clear of the fire. Put the window in a safe place away
from your immediate work area.
17.3 To remove the ceramic fuel effect and rear wall.
Remove the fascia (See section 17.1).
Remove the window unit (See section 17.2)
Lift out the ceramic fuel effect.
Remove the rear wall by carefully sliding it upwards to
clear the retaining channel and then swinging the top
slightly forward.
17.4 To remove the complete burner module.
Remove the fascia (See section 17.1).
Remove the window unit (See section
17.2).
Lift out the ceramic fuel effect and rear
wall (See section 17.3).
Isolate the gas supply using the inlet ‘T’
connector on the appliance.
Unscrew the nut from the top of the inlet
‘T’ connector.
Detach the burner front cover by
unscrewing the 10 screws at the front of
the burner module shown in figure 37.
INSTALLER GUIDE
Figure 36. Window fixing
Figure 37. Burner module fixing screws.
© Baxi Heating U.K. Limited 2009.
Page 37