Unit installation

13. WINDOW FITTING
Fitting the window.
Locate the channel at the top of the window over the top of the firebox opening.
Refit the three spring loaded screws and bushes. The wide part of the bushes
should be in contact with the window frame. Tighten sufficiently to seal the firebox.
Pull the bottom of the window forward and release to check that the window
opens slightly and returns in the event of a delayed ignition explosion.
14. FULL OPERATING CHECKS
14.1 Check for leaks.
Turn on the gas supply and check all joints up to the appliance gas tap for gas
soundness using a soap solution or leak detection fluid.
14.2 Check control operation.
If the fire is turned off or the flames go out, wait at least 3 minutes before
attempting to relight. A safety device in the control stops the fire being turned
back on until it is safe.
(See figure 30).
Turn the left hand control knob fully
clockwise.
Push in the right control knob and, while
keeping it depressed, turn anticlockwise
through the ignition position marked
and up to the pilot position marked
The spark should light the pilot. The pilot
flame can be seen by looking through the
gap near the left side of the ceramic fuel effect front.
If the pilot does not ignite, keep the knob depressed for a few seconds to purge air
from the supply pipes. Then turn back to the off position marked
and repeat the
ignition procedure.
When the pilot has lit, keep the right hand control knob depressed for a few seconds
to allow the pilot flame to stabilise then release it. If the pilot does not remain alight
ensure that the air has been purged.
Partially depress the right control knob and turn to the main burner position
marked . The main burner should now light at its low position.
The left-hand knob is for burner flame adjustment. Turning it anticlockwise should
gradually increase the flame height.