6.3 Preliminary checks.
Check ignition spark (See figure 9).
The pilot burner and electrode unit is at the left
front corner of the burner.
Push in the right hand control knob and turn
anticlockwise through the ignition position marked
and up to the pilot position marked .
A spark should flash across from the pilot electrode
to the pilot burner hood. If there is no spark, check
that the spark gap is as shown.
7. GAS SUPPLY CONNECTION
A nut & olive are provided for an 8mm pipe inlet connection to the inlet ‘T’ connector
at the bottom front of the appliance. This can be rotated to allow a connection from
any direction and includes a valve for isolating the gas supply.
The supply pipe must be rigid material. Flexible pipe must not be used.
Concealed supply pipe connecting from rear of the appliance.
Before the appliance is installed it will be necessary to extend the supply line so that
it will project through the sealed opening at the back of the fire case and run to the
inlet ‘T’ connector at the front.
Make sure that the supply line run up to the rear opening is kept away from the area
that will be taken by the appliance case when it is installed.
Note that when fitted the centre of the appliance inlet ‘T’ connector is 25mm above
the floor.
Cut a slit in the seal at the back of the appliance case. The seal must envelop the
pipe. Do not slit the seal unless the supply pipe is to pass through it.
Cap the open end of any supply pipe installed before the wall is drilled to
prevent any debris or dust etc. entering the pipe.
INSTALLER GUIDE
Figure 9. Ignition
© Baxi Heating U.K. Limited 2009.