Use Instructions

17 of 20 UD00023.01
THIS DOCUMENT AND DATA ARE ISSUED IN STRICT CONFIDENCE AND ARE NOT TO BE
REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION FROM MANAGEMENT
Form TMP_PRD0002.05 Released December 12, 2019
IEC 61000-4-6
150 kHz to 80
MHz
150 kHz to 80
MHz
Recommended separation distance:
80 MHz to 800 MHz
800 MHz to 2.5 GHz
P is the maximum output power rating of the
transmitter in watts (W) according to the
transmitter manufacturer and d is the
recommended separation distance in meters
(m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site
survey
a
, should be less than the compliance
level in each frequency range
b
.
Interference may occur in the vicinity of
equipment marked w
ith the following symbol:
Radiated RF 3 V/m 3 V/m
IEC 61000-4-3
80 MHz to 2.5
GHz
80 MHz to 2.5
GHz
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and
land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be predicted
theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an
electromagnetic site survey should be considered. If the measured field strength in the location in which the
curing light is used exceeds the applicable RF compliance level above, the VALO X curing light should be
observed to verify normal operation. If abnormal performance is observed, additional measures may be
necessary, such as re-orienting or relocating the curing light.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Guidance and Manufacture’s Declaration for recommended separation distances between portable and
mobile RF communications equipment and the VALO X curing light
The curing light is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The user of the curing light can help prevent electromagnetic interference by maintaining a
minimum distance between portable and mobile RF communications equipment (transmitters) and the
curing light as recommended below, according to the maximum output power of the communications
equipment.
Rated maximum
output power
of transmitter
(P in Watts)
Separation distance according to frequency of transmitter
(meters)
150 kHz 80 MHz
80 MHz 800 MHz
800 MHz 2.5 GHz