INSTALLATION
This fireplace is designed and approved for installation with the following brands of chimneys measuring 7”
(178 mm) in diameter as well as a minimum of 15’ (4.6 m) and maximum of 45’ (13.5 m) in height.
CHIMNEY
MANUFACTURER
BRAND TYPE
INNER
DIAMETER
Selkir
k
Ultra-Temp (UT) 1” Solid Pac
k
7" (178 mm)
Selkir
k
Super Pro (SPR) 1” Solid Pac
k
7" (178 mm)
Selkir
k
Super Vent (JSC) 1” Solid Pac
k
7" (178 mm)
Selkir
k
Hart & Cooley (TLC) 1” Solid Pac
k
7" (178 mm)
Selkir
k
Sure-Temp (ST) 1” Solid Pac
k
7" (178 mm)
Selkir
k
CF Sentinel (CF) 2” Solid Pac
k
7" (178 mm)
Selkir
k
Super Pro 2100 (ALT) 2” Solid Pac
k
7" (178 mm)
Selkir
k
Super Vent 2100 (JM) 2” Solid Pac
k
7" (178 mm)
Selkir
k
UltimateOne 1” Solid Pac
k
7" (178 mm)
Security Chimney ASHT+ 1” Solid Pac
k
7" (178 mm)
Security Chimney S-2100 + 2” Solid Pac
k
7" (178 mm)
Simpson Dura Vent Dura Tech 1” Solid Pac
k
7" (178 mm)
Simpson Dura Vent Dura Plus HTC 2” Solid Pac
k
7" (178 mm)
Simpson Dura Vent Dura Plus AC Triple Wall 7" (178 mm)
ICC Excel 2100 1” Solid Pac
k
7" (178 mm)
Metal Fab Temp Guar
d
1” Solid Pac
k
7" (178 mm)
American Metal HSS AC Triple Wall 7" (178 mm)
American Metal HS AC Triple Wall 7" (178 mm)
Olympia Chimney Ventis 1” Solid Pac
k
7" (178 mm)
FMI (U.S.A. only) AC AC Triple Wall 7" (178 mm)
We recommend that our woodburning hearth products be installed and serviced by professionals who are
certified in the United States by NFI (National Fireplace Institute®) or in Canada by WETT (Wood Energy
Technical Training) or in Quebec by APC (Association des Professionnels du Chauffage).
Install the fireplace strictly according to the methods described herein and ensure proper clearance is provided
between the walls. Use only the parts and chimneys specified in this manual. Any non-compliance with these
directions could create a hazardous situation, thus voiding the certification and the warranty.
ATTENTION:
Do not modify or adapt the fireplace’s construction or components. This would void the
warranty. In this event, VALCOURT FIREPLACES INC. would not be held responsible
for any damages which may occur.
No other device must be added to the chimney connected to the fireplace.
Choose the best location for your fireplace based on the position of the doors and windows. Provide for the
positioning of the outside air inlet as well as the chimney. Remember to leave sufficient space for the hearth
extension and mantel. If possible, install the fireplace where it will not be necessary to cut any floor or ceiling
joists.
For optimal performance, install the chimney indoors if possible. In areas where temperatures are consistently
below freezing (32ºF/0ºC), installing the chimney outdoors promotes functional problems such as insufficient
draw, excessive creosoting, and difficult fire ignition. In addition, outdoor chimneys are subject to decreases in