Troubleshooting
Some common problems encountered when the paging system is not operating are
described below. Check each item in the order listed.
1. No AC power to AmpliCenter.
2. Host telephone system failure.
3. Host system page port failure.
4. A hardwire disconnect between host system and PagePac
®
Plus.
5. AmpliCenter switch settings tampered with.
If the problem has not been resolved by checking the preceding items, follow the
steps described in Table 1.
Table 1. Troubleshooting Table
Problem Corrective Action
Page access from telephone system working, but page is
not heard.
No power to AmpliCenter.
Host system not passing call through to AmpliCenter.
Telephone mode selection switch not set correctly for host telephone
system.
Ground start - Tip and Ring reversed or AmpliCenter not grounded.
Audio signal not reaching speakers. Check wiring at AmpliCenter. Verify
Page Accessed LED is on.
Background music cannot be heard. Input level not set correctly. Adjust music input level on AmpliCenter.
No power to music source. Verify power is on.
Radio off station. Adjust tuner.
Music input wires crossed, with signal grounded out.
Distorted, garbled, or raspy sound from all speakers
connected to AmpliCenter.
Short circuited speaker leads. Separate.
Music input level too high. Turn down.
Speaker transformer shorted. Replace.
Failed AmpliCenter. Return for repair.
Green power LED off. AC outlet receptacle is not live. Check outlet circuit breaker or use another
outlet.
Power cord is loose.
Failed AmpliCenter. Return for repair.
Page access LED won’t go off. Page VOX too sensitive. Adjust.
Cl lead is grounded. If loop start or ground start, check that only 2 wires
(Tip and Ring) are connected by the modular plug cord.