Specifications
12
Specifications
Table 3 describes the specifications of the AmpliCenter D300A, D100A and D40 models.
Table 3 AmpliCenter Specifications
! Telephone Paging Access: The AmpliCenter accepts inputs from telephone system (PBX) ground start or
loop start trunk ports, dry loop 600 Ohm page ports, dry loop (hi Z) or amplified microphones.
! Music interface: The AmpliCenter is the unit to which the background music source (CD, radio, tape
player) is connected for distribution to the paging system.
! Volume control: The AmpliCenter has music ducking (Mute) level, music volume level and bass control
adjustment pots on the rear panel. Also Page Cal (Page Volume Calibration).
Features
! Remote amplifier connection: The AmpliCenter provides 0dBm audio output for connection to a remote
amplifier, which receives a contact closure control signal from the AmpliCenter.
Rated Power ! D100A: up to 100 Watts, for a 70V constant voltage distribution system
! D300A: up to 300 Watts, for a 70V constant voltage distribution system.
! D 40: up to 40 Watts, for a 70V constant voltage distribution system.
! D100A: 3.50” (8.89 cm) high x 19.00” (48.26 cm) wide x 7.25” (18.42 cm) deep.Dimensions
! D300A: 3.50” (8.89 cm) high x 19.00” (48.26 cm) wide x 7.25” (18.42 cm) deep.
! D40: 3.50” (8.89 cm) high x 19.00” (48.26 cm) wide x 5.00” (12.70 cm) deep.
Weight ! D100A: 7.6 lbs (3.45 kg).
! D300A: 16. Lbs (7.26kg).
! D40: 5.1 lbs (2.31kg).
Load Impedance ! Minimum, D100A: 50 Ohms
! Minimum, D300A: 16.7 Ohms.
! Minimum, D40: 122 Ohms.
Frequency Response ! 60Hz to 16KHz
Total Harmonic
Distortion
! Less than 1%, at rated power, 60Hz to 16kHz.
Hum and Noise ! Less than 8dB below rated output, 20Hz to 20kHz bandwidth, unweighted.
Telephone Paging
Access
! Automatic Level Control: 15:1 compression ratio above –15dBm input; Gain Below Limiting Knee: 56dB;
ALC Attack Time: Less than 3 msec.
! Sensitivity: 180mV for rated output, single channel input. 90mV with both inputs driven.Music Input
! Impedance: 20 Kohms, unbalanced, each input (left & right)
.
Overload Protection ! Current limiting, thermal shutdown, short circuit, reactive load and internal DC fault protection.
Approvals ! UL Listed for U.S. and Canada, Part 15
! Talk battery: 24 Volts, loop start or ground start, negative voltage ring lead.RJ-11 Jack
Specifications
! Impedance: 600 Ohms and 100 Kohms.
Temperature
! (+32°F to +104°F) (0 to +40°C) operational to +50°C (+122°F) with forced air.
Range
! (-4°F to 158°F) (-20 to +70°C) storage
and shipment.
Environmental
Requirements
! Locate in an area free of excess moisture, corrosive gases, dust and chemicals.
Humidity: 5% to 95%. (noncondensing) storage/shipment and operation. Altitude: sea level to 10,000 ft.
(1048 to 648 millibars) operational, 40,000 ft. maximum shipment.
! Outlet must be a 3-prong outlet, separate ground, not controlled by an on/off switch.Electrical Power
Requirements
! D300A: 8 Amp/4 Amp maximum, 115V/230VAC 60/50Hz
! D100A: 2.5 Amp/1.25 Amp maximum, 115V/230VAC 60/50Hz
! D40: 0.5/0.25 Amp, 115V/230VAC 60/50Hz
! A. Use the power cord supplied with the unit or an equivalent cord that meets applicable safety codes. Do
not cut or remove the third wire ground prong.
Grounding
Requirements
! B. The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding
type and the grounding conductors serving these receptacles are to be connected to earth ground at the
service equipment.










