V-9989 Multi-Messager USB Installation & User Manual Valcom • 5614 Hollins Road • Roanoke, VA • 24019 Support: 1-800-VALCOM1 • HQ: 1-540-563-2000 • FAX: 1-540-362-9800 www.valcom.com • is@valcom.
Index: Introduction ........................................................................................................................3 Multi-Messager USB Layout Summary............................................................................... 4-5 Installation ....................................................................................................................... 6 - 9 Message Programming & Operation.................................................................................
Multi-Messager USB Layout Summary: Front of Unit SPEAKER - The SPEAKER switch can be turned ON and OFF to monitor audio. The switch has no effect on the audio output connections on the rear of the unit. Switch should normally be kept OFF. USB PLUG - The USB drive is inserted here to play audio. If insertion of drive is difficult, turn the drive over and try reinserting. Drive should slide into jack smoothly.
Timer { 1 2 3 4 5 6 7 8 9 10 Trigger Polarity NC/NO Continuous/Play Once Rotate/Standard OFF ON Bottom of unit + Message BGM + - BGM - This pot is used to control the final output level of the background music that is fed through the units BGM INPUT on the I/O CONNECTOR on the rear of the unit. Volume up is counter-clockwise, volume down is clockwise. MESSAGE - This pot is used to control the final output level of the stored messages. Volume up is counterclockwise, volume down is clockwise.
Installation: The Multi-Messager should be installed using the following steps outlined below: Step 1: Wire the terminal blocks that are supplied with the kit. Use the chart below to wire the terminal blocks for the features that are applicable to your application. Two terminal blocks, two RCA audio cords and a screwdriver have been supplied in the accessory kit. The TRIGGER & STOP terminals should use CAT 3/5 wire.
Step 2: Set the DIP switches for the features that will be used. The Mutli-Messager USB has several features that are activated by setting the DIP switches on the bottom of the unit. Changes to these DIP switches must be done with the power OFF. TIMER - DIP switch positions SW1 to SW4 are used to configure the stored message timer for message slots 9 through 99. Use the chart below to configure the timer, if no timer is required turn all switches to the OFF position.
CONTINUOUS TRIGGER/PLAY ONCE - DIP switch position SW6 is used select the play once or continuous trigger feature for message slots 1 through 8 ONLY. When this DIP switch is set to “ON” the unit will play message selected continuously, as long as trigger is applied. When this DIP switch is set to “OFF” the unit will play message selected once, then stop until triggered again. Note: This has no effect on message slots 9 through 99.
Step 3: Install Multi-Messager USB hardware Step 3.1: Wall or shelf mount the unit. Screws and rubber feet are supplied in the accessory kit. Step 3.2: Verify power switch on rear of unit is in OFF position. Attach the included power pack to a wall or power strip receptacle, then attach the other end to the jack on the rear of the unit labeled 12VDC. Tip: Make sure the power receptacle is live 24 hours a day and is not switched off at night. Step 3.
Message Programming & Operation: All messages that are available for the Multi-Messager USB to play are stored on an industry standard USB flash drive. Messages must be labeled correctly so they will automatically be placed into virtual message “slots” on the unit. There are two different type of message slots: 1. Triggered Message Slots – These messages reside in slots 1 to 8 of the USB flash drive and are activated instantly when the corresponding contact closure is activated. 2.
Limited Warranty Valcom, Inc. warrants its products to be free from defects in materials and workmanship underconditions of normal use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any suchdefective device within the warranty period, provided that: 1.inspection by Valcom, Inc. indicates the validity of the claim, 2.
5614 Hollins Road Roanoke, VA 24019 Support: 1-800-VALCOM1 HQ: 1-540-563-2000 Fax: 1-540-362-9800 www.valcom.com is@valcom.com Rev.