User`s guide
User's Guide  ______________________________________________________________________   
Figure 40 and Figure 41 below illustrate the wiring of heated 
WMT700 instruments. 
  1301-018 
Figure 40  Wiring of Heated WMT700 Versions, Part 1 
Note that when using separate power supplies for operating and 
heating, the minus (-) terminals of the power supplies are 
connected together by an additional wire. Use a minimum 
0.75 mm
2
 wire for connecting the (-) terminals together. 
  1307-003 
Figure 41  Wiring of Heated WMT700 Versions, Part 2 
CAUTION 
There are two terminals connected in parallel for both positive and 
negative rails of the heating voltage for the maximum current capacity. In 
case the connection cable has parallel supply wires, they all have to be 
connected to ensure current capacity. Leaving one terminal unconnected 
or connecting it to the ground may cause a WMT700 malfunction or a 
short circuit in
 the power supply. 
88 ___________________________________________________________________ M211095EN-E 