User`s guide
User's Guide  ______________________________________________________________________   
RS485 Cable 2 m and RS485 Cable 
10 m 
RS485 Cable 2 m and RS485 Cable 10 m are designed for the 
standard connection: operating power, heater power, and RS485. 
The two-wire RS485 loopback connections, as shown in Table 24 
below, are preconnected inside the cable. 
Table 24  Connecting RS485 Cable 2 m (228259SP) and 
RS485 Cable 10 m (228260SP) 
Power Supply 
Wire Colors  
Pin 
Operating Power Supply 
White  
1 
Operating Power Supply Ground 
Gray-Pink 
11 
Heater Power Supply 
Gray, Green, Pink 
5, 6 
Heater Power Supply Ground 
Blue, Black, Red, Yellow 
7, 8 
Enclosure Ground 
Shield 
Shield 
COM2 
RS485 - 
Brown 
3,4 
RS485 + 
Red-Blue 
14, 15 
Communications Ground 
Violet 
10 
80 ___________________________________________________________________ M211095EN-E 