User`s guide
Chapter 4 ________________________________________________________________  Installation 
RS485 for COM2 with Cable 2 m and 10 m 
In RS485 mode, the same signals as in RS422 mode are available 
at the end of Cable 2 m and Cable 10 m. Make two-wire loop-
backs at the end of the cable, as shown in Table 23 and Figure 35 
below. 
Table 23  COM2 RS485 Wiring 
WMT700 Signals 
Wire Colors 
Pin 
RS485 Signals 
RxB 
Green 
3 
- 
TxB 
Yellow 
4 
TxA 
Brown-Green 
14 
+ 
RxA 
White-Yellow 
15 
  1009-016 
Figure 35  COM2 RS485 Wiring 
NOTE 
To avoid confusion, the RS485 and RS422 signals of 
WMT700 are 
named as follows:
-
 Inverting: – 
-
 Non-inverting: + 
According to the EIA
-485 standard, the lines are named as follows: 
-
 Inverting: – <=> A  
-
 Non-inverting: + <=> B  
The A/B naming used by some manufacturers is in conflict with the 
standard. To ensure proper operation, verify the polarity of the signals 
when using the device on the bus with signals named as A/B. Opposite 
polarity causes data inversion on the bus, but it does not damage the 
device.