User`s guide
Chapter 4 ________________________________________________________________  Installation 
Wiring 
The 17-pin M23 male connector is located at the bottom of 
WMT700. The connector is used for power supply, digital 
communications, and analog outputs. The signals related to digital 
communications are galvanically separated from the ground. The 
connector type is Hummel 7.106 series. 
Cables 
Ready-made cables are available for use with Vaisala MAWS and 
AWS520 systems. These cables have connectors on both ends. 
There is also a retrofit cable for Vaisala ROSA system in case 
analog output has been used with WS425. 
Vaisala provides open-lead cables for connections to other host 
systems: 
-  Cable 2 m (227567SP) 
-  Cable 10 m (227568SP) 
-  RS485 Cable 2 m (228259SP) 
-  RS485 Cable 10 m (228260SP) 
-  ROSA Cable 10 m for Analog Outputs (231425SP) 
-  Junction Box with Cable 2 m (ASM210719SP) 
Cable 2 m and Cable 10 m carry through all signals from 
WMT700 while the RS485 cables are designed for RS485 
operation with a limited number of wires. The ROSA Cable is 
intended for replacing WS425 with WMT700 in the Vaisala 
ROSA system if WS425 is connected using analog outputs. The 
Junction Box is designed mainly for maritime RS422 operation 
but it can be used whenever a connection longer than 10 meters is 
needed as an entry point for an extension cable. 
Table 22 on page 78 shows how to connect Cable 2 m 
(227567SP) and Cable 10 m (227568SP). Same color coding is 
also used in Junction Box wiring. 
Table 24 on page 80 shows how to connect RS485 Cable 2 m 
(228259SP) and RS485 Cable 10 m (228260SP). 
NOTE 
Wire colors in the tables are not applicable to other cables.
NOTE 
If there are unused wires, make sure that they are unconnected and 
protected. Do not cut off 
any wires. 