User`s guide
User's Guide  ______________________________________________________________________   
Selecting Installation Location 
Finding a suitable site for WMT700 is important for getting 
representative ambient measurements. Select a site that represents 
the general area of interest. Follow the WMO Guide to 
Meteorological Instruments and Methods of Observation WMO-
No. 8, or other application-specific requirements set by various 
organizations, like the International Civil Aviation Organization 
(ICAO). 
It is important to take into account the geography and surrounding 
area to achieve optimum performance. Trees, buildings, or other 
objects situated in the vicinity of WMT700 disturb free air flow 
and thus affect the accuracy of the measurement results.  
Ideally, WMT700 should be higher than any other object within a 
horizontal radius of 300 m. In general, any object of height (h) 
does not remarkably disturb wind measurement at a minimum 
distance of 10 x h. 
When mounting WMT700 on top of a building, the recommended 
minimum height (h) for the mast is 1.5 × the height of the 
building (H). When the diagonal (W) is less than the height (H), 
the minimum height of the mast is 1.5 × W. 
When there is a need to ensure free air flow with a cross arm 
installation, the distance (y) between WMT700 and the mast 
should be more than 20 × the diameter of the vertical mast (z). 
For more information, see Figure 19 on page 59 and follow 
application-specific installation guidelines.  
When mounting two WMT700 wind sensors at the same height, 
make sure that there is a minimum of 10 meters of distance 
between the two devices, as shown in Figure 21 on page 61. If the 
difference in the height of the sensors is at least 0.5 meters, it is 
enough to have a minimum distance of 2 meters between the two 
devices to avoid possible acoustical interference between them.  
WARNING 
If ice or snow accumulates on WMT700 or the mast, it 
can fall and cause 
injury to persons below.
58 ___________________________________________________________________ M211095EN-E 