User`s guide
Chapter 3 _______________________________________________________ Functional Description 
Missing Readings and Error 
Indication 
If WMT700 is not able to measure the wind, it indicates a missing 
reading in the output. Most common reasons for measurement 
problems are foreign objects (such as ice, birds, or other foreign 
objects) on the line of measurement or sound reflections from 
nearby objects (such as wind tunnel walls). 
The default error indication is an out-of-range signal, which is 
more than 10 V or 20 mA, but other error settings can also be 
configured. 
Example 
To set analog output 1 error indication in current mode to 2 mA, 
set the analog output error value to 0.002. Enter the following 
command: 
S aout1err,0.002 
For more information, see section Appendix D, Configuration 
Parameters, on page 205. 