User`s guide
User's Guide  ______________________________________________________________________   
Measurement Methods 
WMT700 measures wind speed and direction either continuously 
or for the duration of the user-configurable averaging time. You 
can select the measurement mode over the serial interface.  
Continuous Measurement 
You can set WMT700 to measure wind data continuously until 
the sensor receives the STOP command. 
The following data communication methods are available: 
-  Poll Mode: You can fetch the most recent data from WMT700 
with the POLL command. You must specify the data message 
identification number in the command. 
-  Automatic Messaging Mode: If the automatic message interval 
is configured, WMT700 sends automatic data messages at 
selected intervals. The data message is user-configurable.  
For information on response delay and timing, see section Serial 
Interface Timing on page 49. 
Wind Measurement on Request 
You can set WMT700 to measure wind speed and direction for a 
specified period of time. The duration of the measurement can 
range from 0.25 seconds to 60 minutes, depending on the 
configured averaging interval. 
You can fetch the required data message from WMT700 in 
measurement mode with the polling command. You must specify 
the data message in the command. 
For information on response delay and timing, see section Serial 
Interface Timing on page 49. 
42 ___________________________________________________________________ M211095EN-E 