User`s guide
Chapter 2 ___________________________________________________________ Product Overview 
Ordering Options 
A WMT700 unit can be configured by ordering options to suit 
versatile customer needs. You can reconfigure the following 
options: 
-  Digital communication interface 
-  Digital communication profile 
-  Digital communication units 
-  Analog output signals for wind speed channel 
-  Analog output signals for wind direction channel 
Measurement Range 
Ordering option 1, Measurement Range, defines the wind speed 
operation range for the sensor. The maximum reported value of 
wind speed 40, 65, or 75 m/s, depending on the selected option as 
shown in Table 5 below. 
Table 5  Measurement Ranges of Different Sensor Types 
Sensor Type 
Measurement Range 
1 
WMT701 up to 40 m/s 
2 
WMT702 up to 65 m/s 
3 
WMT703 up to 75 m/s 
A 
WMT701 up to 40 m/s + Accredited Wind Calibration 
B 
WMT702 up to 65 m/s + Accredited Wind Calibration 
C 
WMT703 up to 75 m/s + Accredited Wind Calibration 
Temperature Range 
Ordering option 2, Temperature Range, defines the operating 
temperature range for the sensor as shown in Table 6 below. 
Table 6  Temperature Ranges 
Option 
Temperature Range 
A 
-10 ... +60 °C 
B 
-40 ... +60 °C 
C 
-55 ... +70 °C 
Note that the temperature range is not connected to heating in any 
way. If you operate in a demanding environmental climate where 
ice accumulation is expected, Vaisala recommends that you use a 
heated sensor; see Option 4 in Table 7 on page 24. 
VAISALA ________________________________________________________________________ 23 