User`s guide
Appendix D ___________________________________________________  Configuration Parameters 
APPENDIX D 
CONFIGURATION PARAMETERS 
This appendix lists the WMT700 configuration parameters. 
Table 66  Parameter Descriptions 
Parameter 
Name 
Default 
Value 
Allowed Values 
Units 
Description 
address 
A 
String with a 
maximum of 40 
characters. 
Address for WMT700. Note that the 
SDI-12, ASCII, NMEA Extended, ASOS, 
and MES12 profiles use the first 
character only.  
SDI-12 only uses digits 1 … 9. 
aout1err 
aout2err 
1000 
0 … 32000  
V, A, 
Hz, % 
Value for AOUT1 and AOUT2 analog 
output if wind measurement fails. 
aout1_g 
aout2_g 
1 
0 ... 100 
Gain for AOUT1 (wind speed) and  
AOUT2 (wind direction). 
aout1_o 
aout2_o 
0 
-10000 … 10000 
Offset for AOUT1 and AOUT2. 
aout1maxv 
aout2maxv 
32000 
0…32000 
V, A, 
Hz, % 
Analog output maximum value for 
AOUT1 and AOUT2. The output is fixed 
to this value. The unit depends on analog 
output mode.  
aout1minv 
aout2minv 
0 
0…32000 
V, A, 
Hz, % 
Analog output minimum value for AOUT1 
and AOUT2. The output is fixed to this 
value. The unit depends on the analog 
output mode. 
aout1mode 
3 
0 = Current 
1 = Voltage 
2 = Frequency 
3 = Disabled 
Analog output mode for AOUT1. 
aout2mode 
7 
4 = Current 
5 = Voltage 
6 = Potentiometer 
7 = Disabled 
Analog output mode for AOUT2. 
autoInt 
1 
0.25 ... 1000  
Resolution: 0.25 
s 
Automatic message interval in seconds. 
This parameter affects both serial 
communication and analog output. 
Do not select a message interval that is 
shorter than the time it takes to send a 
data message. 
autoPort 
1 
1 = COM1 port 
2 = COM2 port 
Serial port to which WMT700 sends 
automatic data messages.  
autoSend 
0 
0 = Automatic 
messages disabled 
1 … 99 
Automatic data message number. 
Selects the data message format for 
automatic messages.  
cal_date 
Wind calibration date.  
This is a read-only parameter. 