User`s guide
User's Guide  ______________________________________________________________________   
Table 60  Outputs 
Property 
Description/Value 
Digital outputs: 
 Communication interfaces 
COM1: RS-485 
COM2: RS-485, RS-422, RS-232, SDI-12 
 Communication protocols 
WMT700, WS425 ASCII, NMEA Standard 
and Extended (version 0183), SDI-12 (version 
1.3), WS425 ASOS, ROSA - MES12, 
Customized 
 Bit rate 
300, 1200, 2400, 4800, 9600, 19200, 38400, 
57600, or 115200 
 Available averages 
Max. 3600 s 
Analog outputs: 
 Wind speed:  
 Frequency push-pull 
Pulse 0 V/10 V: 0 ... 2 kHz (f = 10 Hz/m/s) 
(Load > 10 kohm) 
 Frequency pull-down 
Pulse 0.5 V/V
in
-2 V (11 V min.): 0 ... 750 Hz 
(Load 50 kohm ±20%) 
  Frequency pull-up 
Pulse 1.5 V/V
in
-4 V (8 V min.): 0 ... 750 Hz 
(Load 50 kohm ±20%) 
 Voltage 
0 ... 10 V (U = 100 mV /m/s) 
 Current 
0 ... 20 mA (I = 0.2 mA/m/s) 
 Wind direction: 
 Voltage 
 Current 
 Potentiometer 
0 ... 10 V (U = 20 mV/°) 
0 ... 20 mA (I = 50 uA//°) 
Reference voltage 1 ... 10 VDC 
0 ... V
ref
 represents 0 ... 359° 
Readout update interval 
Max. 4 Hz 
Units available 
m/s, knots, mph, km/h, V, mA, Hz 
Operating mode 
Automatic Message or Poll Mode 
Virtual temperature 
Celsius degrees 
NOTE 
In extreme weather conditions, ice or snow accumulation may cause a 
temporary wind measurement blackout even when the heating is enabled. 
WMT700 indicates this with missing readings or in the data message. 
190 __________________________________________________________________ M211095EN-E 