User`s guide
User's Guide  ______________________________________________________________________   
The response is the following: 
atttn<CR><LF> 
where 
a 
= 
Single-digit WMT700 address that corresponds to the 
first character of the address value 
ttt 
= 
Period of time, in seconds, after which WMT700 has 
the measurement ready 
n 
= 
Number of measurement values WMT700 calculates 
and returns as a response to one or more subsequent 
aD0! commands 
<CR><LF> 
= 
Terminates the response 
Example of the command and response: 
1M! 
10025<CR><LF> 
Interpretation of the example message: 
-  Time after which the measurement is ready: 2 second 
-  Number of returned measurement values: 5 
To fetch the measurement results, use the aD0! command. 
174 __________________________________________________________________ M211095EN-E 