User`s guide
User's Guide  ______________________________________________________________________   
WS425 NMEA Extended Profile (v. 0183) 
When the WS425 A/B NMEA Extended profile is selected, you 
can set WMT700 to send messages based on the configured 
automatic message interval or poll data using the $WIP 
command. 
Configurable Parameters 
Table 47 below lists the configurable parameters and their 
allowed and default values for the WS425 A/B NMEA Extended 
profile. 
Table 47  Configurable Parameters for WS425 A/B 
NMEA Extended Profile 
Parameter 
Default 
Value 
Profile-Specific 
Allowed Values 
Description 
address 
A 
String with 1 character 
Address for WMT700 
autoInt  
1 
0.25 ... 1000  
Resolution: 0.25 
Automatic message interval in seconds. Do 
not select a message interval that is shorter 
than the time it takes to send a data message 
autoPort 
2 
1 = COM1 port 
2 = COM2 port 
Serial port to which WMT700 sends automatic 
data messages 
autoSend 
15 
0 = Automatic 
messages disabled 
15 = NMEA automatic 
data message  
Automatic data message number. Selects the 
data message format for automatic messages 
com1_protocol  
0* 
5 = WS425 A/B NMEA 
Extended 
Profile for serial port COM1 
com2_protocol 
5 
5 = WS425 A/B NMEA 
Extended 
Profile for serial port COM2 
com2_interf 
N/A** 
0 = RS-485 
1 = RS-422 
3 = RS-232 
Interface for serial port COM2 
wndAvg 
3 
0.25 … 3600 
Resolution: 0.25 
Averaging time for wind measurement in 
seconds 
wndOrientation 
0 
0 = Array facing up 
1 = Array facing down 
Orientation of the array of WMT700 
wndUnit 
0** 
0 = Meters per second 
1 = Miles per hour  
2 = Kilometers per hour 
3 = Knots  
Wind speed unit 
wndVector 
0 
0 = Scalar averaging 
Wind averaging method 
* COM1 service port is always by default 0 - WMT700 protocol. This can be 
changed using serial commands if COM1 is needed for protocol-specific 
communication. 
** Wind speed unit and COM2 digital communication interface are defined in 
the order form. Default setting may be any of the allowed options, and it can be 
verified from the unit’s configuration code. 
156 __________________________________________________________________ M211095EN-E 