User`s guide
User's Guide  ______________________________________________________________________   
Table 42  Required Parameters for WS425 Analog 
Output Operation Mode  
Parameter Name 
Default Value 
Allowed Values 
Description of How to Emulate WS425 
aout1err 
1000 
0 …. 32000 
Set 1 for voltage output and 625 for 
frequency output for similar operation as 
with WS425. 
aout1_g 
1 
0 …. 100 
Gain for AOUT1. 
Set 0.017895 for compatibility with WS425 
voltage output. 
Set 11.18 for compatibility with WS425 
frequency output. 
aout2_g 
1 
0 …. 100 
Gain for AOUT2. 
Set 0.0027855 for compatibility with 
WS425 potentiometer output. 
aout1mode 
3 
0 = Current 
1 = Voltage 
2 = Frequency 
3 = Disabled 
Analog output mode for AOUT1. 
Set 1 for WS425 voltage output 
compatibility. 
2 for WS425 frequency output 
compatibility. 
aout2mode 
7 
4 = Current 
5 = Voltage 
6 = Potentiometer 
7 = Disabled 
Analog output mode for AOUT2. 
Set 6 WS425 potentiometer output 
compatibility. 
aout1_o 
aout2_o 
0 
-10000 … 10000 
Offset for AOUT1 and AOUT2. 
Set output offset to 0. 
For configuration instructions, see section Configuration on page 
110. 
140 __________________________________________________________________ M211095EN-E 