User`s guide
Chapter 5 _________________________________________________________________ Operation 
NOTE 
RS
-485 is a half-duplex interface. If the RS-485 interface is used and 
response for parameter setting is enabled (messages parameter is set to 
1)
, a simple terminal program cannot be used for loading parameters 
from file
. 
Example: 
This configuration file contains all the WMT700 parameters that 
are user-configurable.  
S wndAvg,1.00000 
S wndUnit,0 
S wndDirOffset, 0.00000 
S wndOrientation,0 
S wndGustTime,3.00000 
S wndCover,4 
S wndVector,1 
S wndCoast,0.00000 
S autoInt,1.00000 
S autoSend,0 
S autoPort,1 
S com1_baud,4 
S com1_parity,0 
S com1_data,8 
S com1_stop,1 
S com1_protocol,0 
S com1_delay,20 
S com2_baud,4 
S com2_parity,0 
S com2_data,8 
S com2_stop,1 
S com2_protocol,0 
S com2_delay,20 
S com2_interf,0 
S sleepTime,5 
S startDelay,5 
S heaterOn,1.00000 
S freqType,0 
S aout1_o,0.00000 
S aout1_g,1.00000 
S aout1minv,0.00000 
S aout1maxv,32000.0 
S aout1err,1000.00 
S aout1mode,3 
S aout2_g,1.00000 
S aout2_o,0.00000 
S aout2minv,0.00000 
S aout2maxv,32000.0 
S aout2err,1000.00 
S aout2mode,7 
S msg1,\ss$\ws,\wd,\se\sp\cr\lf 
S msg2,2 
S msg3,3 
S msg4,4 
S address,A 
S messages,1 
VAISALA _______________________________________________________________________ 125 