User`s guide
User's Guide  ______________________________________________________________________   
Loading Settings from Configuration 
File 
To facilitate the configuration of WMT700, all settings can be 
configured at once using configuration files. You can send a text 
file containing the configuration settings to the sensor with a 
terminal program, such as Tera Term or Windows
®
HyperTerminal.  
For a list of the parameters and their allowed and default values, 
see Appendix D, Configuration Parameters, on page 205. 
To change the parameters over the RS-485, RS-422, or RS-232 
interface: 
1.  Use the G command to fetch the current WMT700 
parameters. 
2.  Disable error messages with the following command:  
S messages,0 
3.  Copy the values from the terminal program to a file. 
Remove the parameters you do not want to change. Also 
remove the parameter “messages” to avoid switching 
messaging on during the transfer. 
4.  Clear the error counters with the following command: 
CLEARERR 
5.  Send the file to WMT700 to change the settings. 
6.  To verify that the parameters are set correctly (the values 
are in the allowed range and all parameters are valid), read 
the error counters with the following command: 
ERRORS 
If all values are valid, WMT700 sends the following 
response: 
0,0,0,0 
You can also use the G command to check that the 
parameters are set correctly. 
If the response for parameter setting is not disabled (as instructed 
in step 3) but the messages parameter is set to 1 instead, WMT700 
responds to each S command confirming the new parameter 
values. If an error occurs during the configuration, WMT700 
sends a response containing the error messages. 
124 __________________________________________________________________ M211095EN-E 